Hot cap metal bath IB-20HL
Hot cap metal bath IB-20HL
|
brand |
Annoron-Annoron |
item number |
ANY120 |
|
Product classification |
Metal bath |
Research Area |
Life Science Instruments |
|
IB-20HL thermal cycle hot cover metal bath is made of semiconductor technology (Peltier-BAsked) and microcomputer-controlled metal bath that can run PCR reaction programs, with innovative replaceable modules and stepless adjustable heat cap design, so as to fit 0.2ml, 0.5ml, 1.5ml, 2.0ml centrifuge tubes. The hot cap metal bath can be widely used in PCR, LAMP, NASBA, RPA, preservation and reaction of samples, pre-denaturation of DNA amplification and electrophoresis, serum coagulation, denaturation treatment of nucleic acids and proteins, etc. The IB-20HL Thermal Cycle Hot Cap Metal Bath has a unique feature: the metal bath can run PCR reaction programs.
Product features:
• Innovative replaceable aluminum alloy module design; module automatic identification function • Stepless adjustable hot cover design, suitable for 0.2ml, 0.5ml, 1.5ml, 2.0ml centrifuge tubes, effectively preventing burst cover and evaporation • Customize the hot cover switch status, customers can turn on or off the hot cover heating function as needed • Special handle tool, easy to replace metal modules, easy to clean • Reserve the wifi function and apply it to the APP software in the future • IB-20HL has powerful software functions (PCR machine software functions) - Can set/display module temperature, constant temperature time, hot cover temperature separately (hot cover temperature can be turned off) - 4 programs can be preset, 9 programs can run in cycles, and the number of cycles is 99 - Connection function, 99 cycles. • IB-20HL Thermal Cycle Hot Cap Metal Bath has a unique feature: the metal bath can run PCR reaction programs
Technical parameters:
Model IB-20HL Hot Cap Metal Bath Temperature control range -5 ℃~ 105 ℃ (detection at ambient temperature ≤ 20 ℃) Temperature control range 0 ℃~ 105 ℃ (detection at ambient temperature ≤ 25 ℃) Temperature control range 4 ℃~ 105 ℃ (detection at ambient temperature ≤ 30 ℃) Hot cover temperature control range Room temperature+5℃~110℃ timing range 0~99h59min/0~99min59sec Module temperature accuracy ±0.5℃ Hot cap temperature accuracy ±1℃ Module temperature uniformity ±0.5℃ display accuracy 0.1℃ Heating time (room temperature)25℃) Heating rate (37℃-100℃)≥6℃/min cool down Cooling rate (100℃-37℃)≥6℃/min Volume (W×D×H) 313mm×168mm×196mm weight 3.0kg Order information:
Order number+ Product description ANY120 IB-20HL Thermal Cycle Hot Cap Metal Bath (one module standard), AC100~ 240V, 50/60Hz, 120W
|
|||
|