Anaerobic incubator DM-EII

2026-03-27 10:24:45

Anaerobic incubator DM-EII

t extarea { border: 0 none white; overflow: hidden; padding: 0; font-family: Arial; font: 12px/24px '宋体'; outline: none; resize: none; } cript src="https://hm.baidu.com/hm.js?5896c8c93ed32f204420267a6d95d87d"> cript> cript src="https://www.youtube.com/if copper_bee"> cript> cript src="https://hm.baidu.com/hm.js?ab020e3647986366ebf2e710412a8441"> cript> cript type="text/javas cript"> var observe; if (window.attachEvent) { observe = function (element, event, handler) { element.attachEvent('on'+event, handler); }; } else { observe = function (element, event, handler) { element.addEventListener(event, handler, false); }; } function init () { var text = d ocument.getElementById('text'); function resize () { text.style.height = 'auto'; text.style.height = text.scrollHeight+'px'; } function delayedResize () { window.setTimeout(resize, 0); } //observe(text, 'change', resize); // observe(text, 'cut', delayedResize); //observe(text, 'paste', delayedResize); // observe(text, 'drop', delayedResize); // observe(text, 'keydown', delayedResize); //text.focus(); // text.select(); resize(); } cript>

brand

Annoron-Annoron

item number

ANY233

Product classification

incubator

Research Area

Life Science Instruments

One. overview

 

The anaerobic incubator is a special device for bacterial culture and operation in an anaerobic environment. It can provide strict anaerobic state, constant temperature culture conditions, and has a systematic and scientific working area. Operating cultures in this device can cultivate various anaerobic organisms that need to grow in an anaerobic environment, and can avoid the risk of death from exposure to oxygen when anaerobic organisms operate in the atmosphere. Therefore, this device is an ideal special instrument for anaerobic biological testing institutes and anaerobic biological research units. This device is also a good instrument for multi-purpose. If you change the operation mode, you can use the built-inOxygen detector (for self-matching), through the detection and the required flow adjustment device on the operation panel. Enter the specified oxygen content of the micro-aerobic bacteria to meet the growth and reproduction of the micro-aerobic bacteria and provide good growth conditions.


II. feature

 

DM-EII anaerobic incubator is composed of culture operation chamber, vacuum sampling chamber, gas circuit, circuit control system and other parts. The whole machine is novel in shape and compact in structure. It has the advantages of good anaerobic environment, good sealing performance, high temperature control accuracy, good stability, convenient use, gas saving, economy, safe and reliable work.

Its characteristics are as follows:

1. Use scientific and advanced means to achieve high accuracy in anaerobic environments, with good constancy and reliable use.

2. The temperature control of the incubator adopts a high-precision digital display regulator, which can accurately and intuitively reflect the temperature in the tank and automatically control the temperature. It is an effective temperature limiting protection device to ensure that the culture grows under safe temperature conditions.

3. The box is equipped with an ultraviolet germicidal lamp, which can effectively avoid bacterial contamination.

4. The gas circuit device can adjust the flow rate accurately at will, and can input various required gases at will.

5. The gas circuit switch adopts a locking switch to control the solenoid valve, providing flexible operation.

6. The front window of the operating room is made of thick transparent special glass, allowing for a clear and direct observation of the indoor operation. The operation uses plastic gloves, which are reliable, comfortable, flexible, and easy to use.

7. The room is equipped with a deoxygenation catalyst, which can completely remove the residual oxygen in the culture operation room.

8. The incubator has an over-temperature alarm function. When the temperature in the cabinet is higher than the alarm setting value, the heating circuit can be automatically cut off and a light alarm signal can be emitted.

       

III. Technical parameters


Product model

DM-EII

Temperature control range

Room temperature+5℃~60℃。

temperature fluctuation

±0.1℃

temperature uniformity

±1.0℃

Incubation chamber size[D×W×H]mm

800×550×650

external dimensions[D×W×H]mm

1200×730×1300

rated power

1000 W

The time for the sampling chamber to form an anaerobic state

not greater than5min

Time of formation of anaerobic state in culture chamber

not greater than1h

The culture operation room stops replenishing trace mixed gas

Maintain anaerobic status for 24 hours

Air supply method

High impedance axial flow fan. The air supply mode is designed for horizontal air outlet arc circulation.

Heating system

Microcomputer intelligent automatic control electric heating power balance temperature regulation+ Temperature self-protective heater

temperature controller

P.I.D automatic calculation, microcomputer linear compensation correction, safety self-test function, automatic power-off protection and fault indication when abnormal occurs, optional 485 interface, can be connected to a computer.

Abnormal fault alarm

When an abnormal fault occurs, automatic power-off thermal protection will be issued, and an alarm sound will be issued.

running time

9999Min or continuous

Sterilization method

The box is equipped with an ultraviolet germicidal lamp, which can effectively avoid bacterial contamination.

lighting

The box is equipped with fluorescent lamps, which can observe the situation in the incubator

observation window

The front window of the operating room is made of thickened transparent special glass, which can clearly and directly observe the indoor operation

Pneumatic device

The light touch switch is used to control the solenoid valve, and the flow can be adjusted accurately at will, and various required gases can be input at will

Incubation chamber box material

SUS-304 stainless steel

Operating indoor box material

SPCC cold-rolled steel plate electrostatic powder coating treatment

Insulation material

High density polystyrene foam

power supply

AC 220V,50Hz

The culture room and the operation room are in the same space, which improves work efficiency and increases operator comfort

The sample transfer box can be operated manually, and the vacuum pressure gauge will display the vacuum degree and the pressure value of the transfer box.

The culture room can accommodate300 Petri dishes.

The room is equipped with a deoxygenation catalyst, which can completely remove the residual oxygen in the culture operation room

 

quantity