Automatic nucleic acid extractor Auto-Pure 96/48/24

2026-03-27 10:24:45

Automatic nucleic acid extractor Auto-Pure 96/48/24

t extarea { border: 0 none white; overflow: hidden; padding: 0; font-family: Arial; font: 12px/24px '宋体'; outline: none; resize: none; } cript src="https://hm.baidu.com/hm.js?5896c8c93ed32f204420267a6d95d87d"> cript> cript src="https://www.youtube.com/if copper_bee"> cript> cript src="https://hm.baidu.com/hm.js?ab020e3647986366ebf2e710412a8441"> cript> cript type="text/javas cript"> var observe; if (window.attachEvent) { observe = function (element, event, handler) { element.attachEvent('on'+event, handler); }; } else { observe = function (element, event, handler) { element.addEventListener(event, handler, false); }; } function init () { var text = d ocument.getElementById('text'); function resize () { text.style.height = 'auto'; text.style.height = text.scrollHeight+'px'; } function delayedResize () { window.setTimeout(resize, 0); } //observe(text, 'change', resize); // observe(text, 'cut', delayedResize); //observe(text, 'paste', delayedResize); // observe(text, 'drop', delayedResize); // observe(text, 'keydown', delayedResize); //text.focus(); // text.select(); resize(); } cript>

brand

Annoron-Annoron

item number

ANY272

Product classification

Nucleic acid extractor

Research Area

Life Science Instruments

Auto-Pure96/Auto-Pure48/Auto-Pure24 automatic nucleic acid extractor uses magnetic bead separation technology, using 96 deep-well plates, 96 magnetic rod sets (1,000 µL reaction system); 3mL kit, 48 magnetic rod sets (3,000 µL reaction system); 10mL kit, 24 magnetic rod sets (10,000 µL reaction system) with different types of magnetic bead method nucleic acid extraction kits, which can operate 1-96 samples, 1-48 samples or 1-24 samples simultaneously, and can quickly extract DNA and RNA from samples in only 30 to 60 minutes.

  

Product features:

 

• Simple and intelligent operation

Built-in lightingLED, allowing real-time observation of instrument operation

Open the front cover and stop urgently, which is convenient for the optimization and observation of reagents

Intelligent operation, instrument boot self-test, power-off protection, etc

8 board positions automatically identify and position design, no manual adjustment required

• Multiple pollution control

Anti-drip plate design and software control the magnetic bead drying method to prevent liquid splashing during the experiment

Disposable consumables to eliminate inter-hole pollution and batch pollutionWith built-in disinfection function, UV disinfection can be performed regularly

• Reliable structure and stable operation

Adopt screw drive to achieve lifting movement, with high precision

The special structure design of the center turntable allows for a smaller instrument footprint

Specially designed magnetic rod sleeve automatic loading and unloading structure, the success rate is close to100%

• High quality and fast extraction

Can be processed simultaneously at most96 1mL samples

Auto-Pure24 Maximum sample processing volume 10mL

Effectively avoid the influence of human factors on the experiment

Open design, free program editing

Room temperature+ 5 ℃ -120 ℃ temperature precise control

Program editing can be realized on a single machine

The software has complete functions and is suitable for all kinds of magnetic bead reagents

Mixing and magnetic absorption methods are diverse, which is conducive to reagent optimization

 

Technical parameters:

 

Model

Auto-Pure96/Auto-Pure48/Auto-Pure24 Automatic Nucleic Acid Extractor

sample flux

1~96(Auto-Pure96);1~48(Auto-Pure48);1~24(Auto-Pure24)

processing volume

50~1000µL(Auto-Pure96);50~3000µL(1~48);50~10000µL(Auto-Pure24)

Use consumables

96 deep well plate + 96 magnetic rod sleeve (Auto-Pure96); 3mL kit + magnetic rod sleeve (Auto-Pure48); 10mL kit + magnetic rod sleeve (Auto-Pure24)

principle/working mode

Magnetic bead method, magnetic bar type /Circular turntable type

purification sensitivity

Positive detection rate of 100 copies of samples > 95%

purification pore difference

CV<5%

Bead collection rate

>95%

pyrolysis temperature

Room temperature~120℃

elution temperature

Room temperature~120℃

oscillatory mixing

Can edit a mix of different needs

operation interface

7 touch screen, 3 shortcuts, external mouse

internal program

preset8 sets of programs, 100 sets of programs can be stored

program management

Create, edit, save as, delete, etc

Instrument Expansion Interface

standardUSB, Ethernet port, wireless wifi

lighting system

Yes.

sterilization

UV disinfection

Exhaust method

Fan

data storage

Stored, built-inSD card

Maximum input power

300W

volume

56cm×62cm×50cm

weight

54kg

 

Order information:

 

Order number+ Product description

ANY272

Auto-Pure96 Automatic Nucleic Acid Analyzer

ANY031-01

Auto-Pure96 Magnetic Rod Cover

ANY031-02

Auto-Pure96 Kit

ANY273

Auto-Pure48 Automatic Nucleic Acid Extractor

ANY032-01

Auto-Pure48 Magnetic Sleeve

ANY032-02

Auto-Pure48 Kit

ANY274

Auto-Pure24 Automatic Nucleic Acid Extractor

ANY033-01

Auto-Pure24 Magnetic Stick Cover

ANY033-02

Auto-Pure24 Kit

ANY262

FCM-1 Nucleic Acid Kit Automatic Film Cutting Machine

ANY261

SealBio-2 Microplate Heat Sealer

ANY027-03

SBA-3 laminated copper sheet

ANY027-04

Seal-150 transparent peelable heat sealing film

ANY027-05

Seal-200 Peelable Heat Seal Film for Compound Storage

ANY027-06

Seal-300 Pierceable Heat Sealing Aluminum Film


quantity

nclick="reduce_pay(256420);">
nclick="add_pay(256420);">
Customer service