Infrared inoculation ring sterilizer HM-3000A

2026-03-27 10:24:45

Infrared inoculation ring sterilizer HM-3000A

t extarea { border: 0 none white; overflow: hidden; padding: 0; font-family: Arial; font: 12px/24px '宋体'; outline: none; resize: none; } cript src="https://hm.baidu.com/hm.js?5896c8c93ed32f204420267a6d95d87d"> cript> cript src="https://www.youtube.com/if copper_bee"> cript> cript src="https://hm.baidu.com/hm.js?ab020e3647986366ebf2e710412a8441"> cript> cript type="text/javas cript"> var observe; if (window.attachEvent) { observe = function (element, event, handler) { element.attachEvent('on'+event, handler); }; } else { observe = function (element, event, handler) { element.addEventListener(event, handler, false); }; } function init () { var text = d ocument.getElementById('text'); function resize () { text.style.height = 'auto'; text.style.height = text.scrollHeight+'px'; } function delayedResize () { window.setTimeout(resize, 0); } //observe(text, 'change', resize); // observe(text, 'cut', delayedResize); //observe(text, 'paste', delayedResize); // observe(text, 'drop', delayedResize); // observe(text, 'keydown', delayedResize); //text.focus(); // text.select(); resize(); } cript>

brand

Annoron-Annoron

item number

ANY303

Product classification

Infrared sterilizer

Research Area

Life Science Instruments

The HM-3000A infrared inoculation ring sterilizer adopts infrared heat energy sterilization. Because of its convenient use, simple operation, no open flame, no fear of wind, and safe use, it can be widely used in biological safety cabinets, purification workbenches, next to extractor fans, and moving cars for microbial experiments. The temperature in the heating hole can reach more than 800 ° C, and sterilization only takes 5 to 7 seconds; ash organic substances in the depths of ceramic pipes to prevent cross-contamination; connect seed rings, inoculation needles, scissors, forceps, etc. to achieve one-time sterilization effect.

  

Product features:

 

• Inoculation ring or needle sterilization is safe, convenient, and completely replaces alcohol lamps

• The temperature in the heating hole can reach above 800 ° C, and sterilization only takes 5 to 7 seconds

• Small size, light weight, easy to operate; the instrument is beautiful, easy to clean, and has a long service life

The device can be used in anaerobic chambers

• Ash organic matter deep in the ceramic funnel pipe to prevent infectious splashing and cross-contamination

The working environment

 --Ambient temperature: -10 ℃~ 50 ℃

 -- Relative humidity: ≤ 90%

 -- Maximum altitude of use environment: unlimited

 

Technical parameters:

 

Model

HM-3000A Infrared Inoculation Ring Sterilizer

Central maximum temperature

825℃±50℃

Maximum outer diameter of sterilized items

Φ14mm

Head of heating area

150mm

volume(W×D×H)mm

185mm×98mm×185mm

power supply

170W

net weight

1.3kg

 

Order information:

 

Order number+ Product description

ANY303

HM-3000A Infrared Inoculation Ring Sterilizer, AC220V/AC120V, 50/60Hz, 1A

ANY001-03

HM-3000A heating body

ANY001-04

HM-3000A Adaptive Inoculation Ring Stent


quantity

nclick="reduce_pay(256444);">