Automatic vacuum drying oven, after years of actual operation in customers, the demand for parameters. A vacuum drying oven designed to be more stable for experimental parameters and more convenient for operation. The successful test of box heating, through continuous research, broke through the traditional technology to creatively solve the problem in the heat conduction process"Bottleneck" to find the conduction method. Widely used in biochemistry, chemical and pharmaceutical, medical and health, agricultural research, environmental protection and other research application fields, for powder drying, baking and disinfection and sterilization of various glass containers. Especially suitable for drying heat-sensitive, easily oxidized substances and complex ingredients for fast and efficient drying treatment.
Automatic main parameters:
1. With an automatic vacuum system, the vacuum requirement value can be set. When the vacuum value is less than the vacuum value, the vacuum pump will automatically open and extract excess gas. Automatic control of vacuum degree. 2. With an automatic exhaust system, when closing the vacuum box, there is no need to manually twist the exhaust knob. Just turn on the exhaust switch, there is an exhaust solenoid valve control, and the gas is discharged. The solenoid valve automatically closes. 3. With an automatic inert gas intake system, if you need to fill with inert gas, just turn on the intake switch. After the intake is completed, the intake switch can be turned off. 4. Equipped with an automatic air extraction system, controlled by a solenoid valve. 5. With automatic program temperature control function, program LCD controller. 6. The inner tank is equipped with an illumination system, which is conducive to the observation of the sample drying process. 7. The vacuum pump does not require an external power supply. The vacuum pump power socket can be directly connected to the device, eliminating the problem of external power supply for the vacuum pump. 8. The switch design is beautiful, and the power switch is waterproof.
Main features:
● The cuboid studio is made of 304 stainless steel plate to ensure the durability of the product. Tempered, bulletproof double-glazed doors can be used to observe the objects in the studio at a glance. ● The closure and tightness of the box door can be adjusted, and the integrally formed silicone rubber door sealing ring ensures a high vacuum in the box. Storage, heating, testing, and drying are all carried out in an environment without oxygen or filled with inert gas, so it will not oxidize. ● Microcomputer intelligent temperature controller, with setting, measuring temperature dual digital display and PID self-tuning functions, stable and reliable temperature control. The heating power ratio can be adjusted arbitrarily to ensure that the low-end temperature control has no temperature drawbacks.
Technical parameters:
|
Model |
DM-ET50A |
DM-ET30A |
DM-ET20A |
|
Equipment specifications |
Desktop |
Desktop |
Desktop |
|
Automatic vacuum control |
digital display |
digital display |
digital display |
|
Extraction |
Solenoid valve automatic control |
Solenoid valve automatic control |
Solenoid valve automatic control |
|
intake |
Solenoid valve automatic control |
Solenoid valve automatic control |
Solenoid valve automatic control |
|
exhaust |
Solenoid valve automatic control |
Solenoid valve automatic control |
Solenoid valve automatic control |
|
lighting |
LED lighting system |
LED lighting system |
LED lighting system |
|
temperature control |
External heating independent temperature control |
Baffle single temperature control |
Baffle single temperature control |
|
external dimensions(mm) |
710×500×530 |
610×445×480 |
590×425×460 |
|
Inner tank size (mm) |
420×370×350 |
300×320×320 |
300×280×300 |
|
Volume (L) |
50 |
30 |
20 |
|
power supply voltage |
220V 50HZ |
220V 50HZ |
220V 50HZ |
|
power consumption(W) |
1450 |
500 |
400 |
|
baffle(PCS) |
2 |
1 |
1 |
|
temperature resolution(℃) |
0.1 |
0.1 |
0.1 |
|
temperature fluctuation(℃) |
±0.5 |
±0.5 |
±0.5 |
|
Temperature control range (℃) |
RT+10~250 |
RT+10~250 |
RT+10~250 |
|