All
Chemical Reagents
Biomedicine
Organic raw materials
Inorganic chemical industry
intermediate
Agricultural chemicals
Auxiliaries and catalysts
Fragrances and Flavors
Dyes and Pigments
Daily chemical industry

Coppersensor 1

CAS number:874748-20-6    molecular formula:C30H50BF2N3S4

overview

compound introduction

Coppersensor-1 (CS1) is a membrane-permeable fluorescent dye. Coppersensor-1 has a picomolar affinity for Cu + with high selectivity over competing cellular metalions. Coppersensor-1 as a probe, can selective and sensitive detection of copper(I) ions (Cu + ) in biological samples, including live cells. Coppersensor-1 can be used for the research of imaging of severe diseases such as cancer , cardiovascular disorders and neurogenerative diseases. In Vitro Guidelines (Following is our recommended protocol. This protocol only provides a guideline, and should be modified according to your specific needs). A. Preparation of reagent stock solutions for imaging: 1. Prepare a 1 mM stock solution of CS1 (MW 630 g/moL) in DMSO by dissolving 0.63 mg of solid CS1 per milliliter of DMSO solvent. 2. Prepare a 10 mM stock solution of CuCl 2 (MW 134 g/moL) by dissolving 1.34 mg of solid CuCl 2 per milliliter of Millipore water solvent. B. CS1 labeling of live cells: 1. Imaging experiments with cells will require 1-2 d with cells in culture. Incubate the cells according to your normal protocol. 2. One day before imaging, cells are passaged and plated on 18-mm glass coverslips coated with poly-L-lysine (50 μg/mL). Adherent cells for imaging are grown to 50-80% confluency. 3. Remove cells from incubator, and transfer one coverslip into a 35-mm Petri dish containing 3 mL PBS buffer. 4. To the Petri dish, add 15 μL of a 1 mM CS1 stock solution to give a final dye concentration of 5 μM. Mix thoroughly. (Higher concentrations of dye may result in high levels of background fluorescence) 5. Incubate for 5-20 min in the dark at 25 or 37℃. C. Imaging the CS1-labeled cells: 1. Imageing in standard confocal microscope with 543 nm excitation. (CS1 can be imaged using any type of fluorescence microscope, including epifluorescence, confocal and multiphoton) MCE has not independently confirmed the accuracy of these methods. They are for reference only. Form:Solid

Specs

Chinese alias铜传感器1
English alias-
CAS number874748-20-6molecular formulaC30H50BF2N3S4
molecular weight629.81 g/molExact mass-
PSA-logp-

numbering system

No numbering system information yet

physicochemical properties

No physical and chemical property information yet

Safety information

No safety information yet

Production methods and uses

No production method and use information yet

Related

upstream information

No upstream information yet

downstream information

No downstream information yet

MSDS

Found 0 shareMSDS