- Health hazard: 靶器官: 眼睛, 皮肤, 呼吸系统 (NIOSH, 2024)
- Hazard summary: 在啮齿动物为期2年的喂养研究中观察到肝毒性;两名患者在接触含有 Santonox 的乳胶手套后出现接触性皮炎,并进行了阳性斑贴试验,但其他三项研究未发现皮肤致敏的证据;TLV 基础是呼吸道刺激;[ACGIH] 皮肤、眼睛和呼吸道刺激物;[CAMEO]
- reactive group: 苯酚和甲酚
- First aid measures: 吞食:立即就医 - 如果此化学品已被吞食,请立即就医。
- flammable limit: 易燃性:可燃固体
- exposure pathway: 吸入,食入,皮肤和/或眼睛接触
- Harmful effect: ACGIH 致癌物 - 无法分类
- fire hazard: 该化学品可燃。(NTP, 1992)
- fire fighting: 涉及该化合物的火灾可以用干化学品、二氧化碳或哈龙灭火器控制。(NTP, 1992)
- Target Organs: 眼睛、皮肤、呼吸系统
- reactivity profile: 4,4'-硫代双(6-叔丁基间甲酚)可能对光敏感。
- Symptoms and Signs: 眼睛、皮肤、呼吸系统刺激
- Air and water reaction: 对碱水解敏感,可能在溶液中自发氧化。(NTP, 1992)。不溶于水。
- Hazard categories and classifications: 特定靶器官毒性 - 重复接触 - 第2类(肠道、肝脏)
- Non-fire leakage response: 储存注意事项:应保护该材料免受光照,并在室温下储存。(NTP, 1992)
- Personal protective equipment (PPE): 变更:未建议工人在工作班次后更换衣物。(NIOSH, 2024)
- Protective Action Standards (PAC): PAC-3: 460 [mg/m3]
- Carcinogen Classification: 摘要:与TBBC暴露相关的非肿瘤病变包括:雄性和雌性大鼠肝脏的库普弗细胞肥大、细胞质空泡化和混合细胞灶,雌性大鼠肝脏的脂肪变性,以及雌性大鼠肾脏肾病的严重程度增加。此外,雌性大鼠乳腺中纤维腺瘤、腺瘤或癌(合计)的发生率降低。雄性小鼠肝脏中脂肪变性、透明细胞灶以及腺瘤或癌(合计)的发生率也降低。
- Respirator Recommendations: 关于呼吸器选择的重要补充信息
- Threshold Limit Values (TLV): TLV-TWA(时间加权平均):1 mg/m³(可吸入颗粒物)[2010]
- Permissible Exposure Limit (PEL): TWA 15 mg/m3 (总量) TWA 5 mg/m3 (呼吸性) 见附录G
- Recommended Exposure Limit (REL): TWA 10 mg/m3 (总) TWA 5 mg/m3 (呼吸)
- Immediately Dangerous to Life or Health (IDLH): 参见:IDLH 索引
Warm reminder:
Because the manufacturer may temporarily adjust product specifications, prices, inventory, parameters and other information without notice, and there are differences in each user's consultation time and procurement needs, the platform reply content is only of reference value within a certain period. Sorry for the inconvenience caused to you, and thank you for your understanding and support! Please consult the online customer service for the latest details. Everything is subject to the real-time reply of the customer service.!
Please check the quantity, appearance and product information in time when you receive the goods. In case of damage, wrong delivery, abnormal quality and other problems, please feel free to contact us.
Service Hotline:400-6226-992 ,We will handle it for you as soon as possible, thank you for your support and trust.!
4, 4'-thio (6-butylm-methyl) 98% 5/g
4, 4'-thio (6-butylm-methyl) 98% 5/g Macklin 96-69-5, available in complete specifications for production, research, laboratory testing and inspection; digital one-stop procurement platform for scientific materials