t extarea { border: 0 none white; overflow: hidden; padding: 0; font-family: Arial; font: 12px/24px '宋体'; outline: none; resize: none; } cript src="https://hm.baidu.com/hm.js?5896c8c93ed32f204420267a6d95d87d"> cript> cript src="https://www.youtube.com/if copper_bee"> cript> cript src="https://hm.baidu.com/hm.js?ab020e3647986366ebf2e710412a8441"> cript> cript type="text/javas cript"> var observe; if (window.attachEvent) { observe = function (element, event, handler) { element.attachEvent('on'+event, handler); }; } else { observe = function (element, event, handler) { element.addEventListener(event, handler, false); }; } function init () { var text = d ocument.getElementById('text'); function resize () { text.style.height = 'auto'; text.style.height = text.scrollHeight+'px'; } function delayedResize () { window.setTimeout(resize, 0); } //observe(text, 'change', resize); // observe(text, 'cut', delayedResize); //observe(text, 'paste', delayedResize); // observe(text, 'drop', delayedResize); // observe(text, 'keydown', delayedResize); //text.focus(); // text.select(); resize(); } cript>

brand

Annoron-Annoron

item number

AS000008

Product classification

alpha-glucosidase

Research Area

productnameperoxidase-conjugated streptavidin

Code number:AS000008

Physical state:lyophilized powder

Specifications100 µg

Streptavidin concentration:0.7 mg/mL

Recommended work concentration:

0.01-0.1 μg/mLforECLWestern blot of substrates

1-2 μg/mLforELISAThe immune tissue/Cytochemical and chromogenic substrates immunoblot

Peroxidase:From horseradishrhizomemedium purification

buffer0.01MSodium phosphate,pHvalue is74

Stabilizer:15mg/mLBovine Serum Albumin (None)IggNo protease.

Preservatives:none

Storage andresolutionStore freeze-dried solids in2-8℃Use1.0Ml deionized waterresolution, centrifuge if not clear. Prepare the work dilution on the day of use. The product acts as an undiluted liquid in2-8℃Approximately stable6Week.

After resolutionExtended storage:Packed and in-70℃Or freeze below. Avoid repeated freezing and thawing. Alternatively, add an equal volume of glycerin (ACSGrade or higher) to achieve a final concentration of50%And stored in liquid form-20℃under conditions

Expiration date:fromresolutionFrom date1Years. The valid period may be extended if the test results are appropriate for the intended use.

Warning:Before adding to this product, please confirm that the glycerin isACSGrade 1 or higher. Lower grades of glycerol may severely inhibit peroxidase activity.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test effect comparison:

 

In multiple batchesDuring the Elisa detection verification process, the trial pack 2 has the same detection signal sensitivity and lower non-specific signal than Jachson. It is recommended thattrial package1The concentration used is1-2Mg/mL, recommendedThe usage concentration of the trial package 2 is 1-2ug/mL, and the customer can optimize the usage concentration of Streptavidin-HRP according to the application scenario in actual testing.